DC10K and DC10G are controllers for manual engine start and stop. The 4-digit LED digital tube displays the frequency, voltage, battery voltage, and accumulated working time of the generator set. It has a variety of parking protection and alarm indication functions, and can conveniently monitor the working status of the generator set.
The controller can be connected to the computer through a data cable, and the controller parameters can be set through the software to facilitate matching of generator sets with more specifications.
main feature:
Controlled by a 32-bit imported high-performance microcontroller;
4-digit digital tube display, can be switched automatically or manually;
Using car starter key, durable;
Equipped with parameter setting function, parameters can be set through computer connection;
Equipped with a variety of alarm protection functions;
Equipped with a waterproof ring as standard, the rear panel is splash-proof after installation;
All connections are completed through European-style terminal blocks, making it very easy and convenient to assemble, connect, repair and replace the equipment;
Parameter display
Generator voltage V;
Generator frequency Hz;
Engine battery voltage V;
The cumulative operating time of the unit is H;
Alarm protection
speeding
Overclocking
low oil pressure
high water temperature
External instant parking alarm
Generation overvoltage
Charging failure warning
Specifications
project
Parameters
Operating Voltage
DC8V to 33V continuous power supply
Machine power consumption
Standby: 24V: MAX 1W
Operation: 24V: MAX 2W
AC voltage input
One phase two wires 15VAC-300VAC 50/60Hz
Engine speed signal range
300-10000Hz
Maximum cumulative running time
9999 hours (minimum storage time 6 minutes)
fuel output
Max 16Amp DC+VE supply voltage output
Motor output
Max 10Amp DC+VE supply voltage output
Alarm Output
Max 16Amp DC+VE supply voltage output
Excitation output
Maximum 80mA DC+VE supply voltage output
Switch input
Effective when connected to the negative pole of the battery
Insulation level
When AC2.2kV voltage is applied between the AC high-voltage terminal and the low-voltage terminal, the leakage current shall not exceed 3mA within 1 minute.
working conditions
-30-75℃
storage conditions
-40-85℃
Dimensions
78mm×78mm×72mm
Hole Size
67mm×67mm
weight
0.28Kg