Sensing Input Voltage:170 ~ 510 VAC, Single Phase 2 wires (Voltage is DIP Switch selectable)
Frequency:50 / 60 Hz, DIP Switch selectable
Power Input Voltage:60 ~ 300 VAC, Single Phase 2 wires
Output Voltage:Max. 90 VDC @ 240 VAC input
Current :Continuous 16A
Intermittent:20A for 10 sec
Resistance: Min. 5 ohm
Voltage Regulation: <± 0.5% ( with 4% engine governing )
Voltage Build-up:Residual voltage at AVR terminal > 5 VAC
Thermal Drift:0.03% per °C change in AVR ambient
Load Current Compensation:1A or 5A Max. 7% @ PF0.5 DIP Switch Selectable
Analogue Voltage Input:Max. ±5VDC. ±10% @ ±3VDC
Over Excitation Protection:Max Output DCV 95% 20 Sec
External Volts Adjustment:± 5% with 2K ohm 1 watt trimmer
Unit Power Dissipation:Max. 10 watt
Under Frequency Protection ( Factory Setting ):50/60 Hz DIP SW selectable
Soft Start Ramp Time:2 sec.