Specification
Induction/Power Input
Voltage: 40-150Vac, three-phase
Frequency: 50/60Hz bridge optional
output
Voltage: Max. 160Vdc to 120Vac input
Current: 8A max
Voltage Regulation: < +/-0.5% (4% motor regulation)
feature
* Voltage regulation <+/-1%
* Soft start voltage ramp * Voltage
loss of protection sensing
* 120 or 240 Vac sensing, jumper selectable
* Low frequency roll-up protection
* With low frequency LED indicator
Details:
Voltage regulation at steady state and constant speed +/-0.5%
Phase-to-phase voltage sensing
Controlled by a transistor means that the quality of regulation is of the applied load
Integrated "LAM" system for increased engine load
Suitable for high levels of viruses and harsh environments
R438 is compatible with other modules that provide additional functionality
Standard power supply: AREP or PMG
Rated overload current: 8A-10s
Electronic protection (overload, voltage induction circuit open circuit short circuit excitation overload current recovers to about 1A after 10 seconds).
Fuse: F1 on X1, X2.8A; slow-250V
Voltage sensing: 5VA, isolated by transformer
0-110V terminal=90-140V
0-220V terminal=170-260V
0-380V terminal=340-520V
Voltage regulation +/-1%
Normal or fast response time via ST2 jumper
Voltage adjustment via potentiometer P2
Current sensing (parallel): C.T. 2.5VA cl1, secondary 1A (optional)
Quadrature drop adjustment via potentiometer P1
Maximum, excitation current is adjusted by P5
For alternators: LSA 42.2, 43.2, 44.2
Compatible with AREP or PMG exit systems